To access the advanced settings of your THERMOSTAT you must turn off the device and hold down the M and keys for 6 seconds.
To navigate through each of the settings press the M button; to adjust the value in each menu use the arrows .
Menu | Description | Adjustment range | Default value |
01 | Calibrate internal sensor | -8ºC ~ 8ºC | 0ºC |
02 | Maximum configurable temperature | 5ºC ~ 35ºC | 35ºC |
03 | Minimum configurable temperature | 5ºC ~ 35ºC | 5ºC |
05 | Antifreeze function | 5ºC ~ 15ºC | 5ºC |
09 | Hysteresis | 0.5ºC ~ 3ºC | 0.5ºC |
11 | Screen lock |
0: disabled 1: enabled |
0 |
12 | Open Window Detection (OWD) |
0: disabled 1: enabled |
0 |
13 | OWD detection time | 2 ~ 30mins | 15mins |
14 | OWD temperature drop | 2ºC ~ 4ºC | 3ºC |
15 | Time to deactivate OWD | 10 ~ 60mins | 30mins |
17 | Factory reset |
0: No 1: Yes (then press the |
0 |
18 | Software version | Read-only version | |
31 | Software sub-version | Read-only version | |
32 | Standby screen brightness adjustment (only when using USB power supply) | 0 ~ 100% | 40% |
To exit advanced settings, press the button or wait approximately 12 seconds without touching any button for it to automatically exit and save the settings.